Oval Gear and Helical Rotor flow meters use positive displacement, well suited to viscous liquids such as oils, resins, adhesives and similar process fluids — the Oval Gear range covers 0.5 L/H to 1,50,000 L/H.
Electromagnetic, vortex, swirl and thermal mass technologies measure flow without moving parts in the flow path, which helps with wear and long-term reliability.
Yes — HART and RS-485 / Modbus communication are available on applicable models, alongside 4–20 mA, pulse and alarm outputs.
Coverage spans from DN4 oval gear meters up to DN2500-class electromagnetic meters and DN4000 thermal mass insertion probes, depending on the technology.
Select products carry ATEX and IECEx protection ratings for use in applicable hazardous-area installations — confirm the exact rating against your installation requirements.
CE, ISO 9001:2015, DNV-GL, IBR Approved, Legal Metrology (Government of India), CIMFR and ATEX, across applicable product lines.
At a 1,00,000 sq ft facility on 25,000 sq ft of land in Mehsana, Gujarat, India — housing design, manufacturing, testing and service under one roof, established in 2006.
Yes — BROIL runs a fully automatic, computerized testing laboratory for flow (1 L/h to 20,00,000 L/h), gas flow (1 m³/h to 10,000 m³/h) and pressure (up to 40 Bar).
Yes — the Fuel Consumption Meter uses two sensors (supply and return line) with a fuel calculator, and the Vehicle Fuel Management System adds GPS tracking, fuel level and travel-route logging.
Email info@broiltech.com, call the numbers on our Contact page, or use the spec-request form — an engineer will confirm the right technology for your application.