The thermal mass flow meter operates on the principle of thermal dispersion — gases conduct heat differently than other substances. The meter carries two temperature sensors: a heated sensor and a reference sensor, maintaining a constant temperature difference between them. As gas flows through the meter it cools the heated sensor, and the flow rate is directly proportional to the amount of cooling. Measuring the temperature difference between the two sensors gives the gas flow rate directly.
Primarily used for measuring the flow of gases — air, natural gas, nitrogen and other process gases — without needing recalibration for composition changes. Common in chemical processing, HVAC systems and environmental monitoring.
Click any industry to see the full product list for it, or tell us your process and we will confirm the match.
Thermal Mass reads true mass flow directly from the gas's heat-loss characteristics, with no need to recalibrate when gas composition changes — Vortex and Swirl are volumetric and suit a narrower set of gas types at higher velocities.
±1% accuracy, covering velocities of ±0.1 to 100 Nm/s and pipe sizes from DN15 to DN4000, 1 to 7,00,000 Nm³/h.
-20°C to 240°C, in SS-316, Hastelloy or PTFE-coated sensor housings depending on the gas's corrosivity.
Insertion type suits large ducts where a full flange run isn't practical; flange end suits smaller, standard pipe runs. Tell us your duct or pipe size and we'll confirm which fits.
Fast — the sensor has no moving parts and a quick thermal response, so it tracks real-time changes rather than averaging over a long window.
Yes, if it reaches the sensor. Condensed droplets hitting the heated element pull heat away much faster than dry gas does, so the meter reads a spike that isn't real flow. If your gas is anywhere near saturated, the fix is installation, not the sensor: keep the line above the dew point where possible, mount the sensor angled so any condensate drains away rather than pooling on it, or fit a knockout drum upstream to pull moisture out before the gas reaches the meter. Tell us if your gas is wet and we'll advise on mounting.
Yes — the meter is calibrated against the thermal properties of the specific gas (or gas mixture) you tell us you're measuring, because different gases carry heat away from the sensor at different rates for the same mass flow. A consistent gas like nitrogen or dry compressed air rarely needs attention. A variable mixture like biogas, where methane and CO2 content can drift, needs the composition range confirmed upfront so we calibrate for the actual swing, not just a single snapshot.
| DN (mm) | Max Flow Rate (Nm³/hour) |
|---|---|
| 15 | 65 |
| 25 | 175 |
| 32 | 290 |
| 40 | 450 |
| 50 | 700 |
| 65 | 1200 |
| 80 | 1800 |
| 100 | 2800 |
| 125 | 4400 |
| 150 | 6300 |
| 200 | 10000 |
| 250 | 17000 |
| 300 | 25000 |
| 400 | 45000 |
| 500 | 70000 |
| 600 | 100000 |
| 700 | 135000 |
| 800 | 180000 |
| 900 | 220000 |
| 1000 | 280000 |
| 1200 | 400000 |
| 1500 | 600000 |
| 2000 | 700000 |