BROILTECH launched an offline fuel consumption meter for vehicle and diesel generator fuel management. FCM combines two fuel flow sensors — one for the supply line and one for the return line — with a fuel calculator. The fuel calculator is available with digital MODBUS RS232/485 output for external communication.
Highly reliable, accurate fuel consumption measurement in trucks, tankers, infrastructure and construction machinery, agriculture machinery, river boats and diesel engines — defining an accurate fuel consumption figure that's otherwise difficult to isolate from a vehicle.
Click any industry to see the full product list for it, or tell us your process and we will confirm the match.
It uses two flow sensors — one on the supply line to the engine, one on the return line — and calculates the difference, so what's actually burned is isolated from what's just recirculated.
Any diesel engine — trucks, tankers, infrastructure and construction machinery, agriculture machinery, river boats and generators.
Digital MODBUS over RS232 or RS485, so it integrates with an existing fleet telematics or SCADA/PLC system rather than needing a standalone display.
9 V DC to 24 V DC, which covers most vehicle and genset electrical systems directly.
Yes — it indicates total consumption, flow rate, and total time for both the supply and return lines.
Because on most diesel engines the injection system returns a large share of what it draws — on some engines the return flow runs close to the supply flow — so a single sensor on the supply line mostly measures fuel being recirculated, not burned. Reading both lines and taking the difference is the only way to isolate actual consumption, which is exactly why this is built as a two-sensor differential system rather than a single inline meter.
Yes — that's one of the more common reasons fleets install a system like this. Because it logs actual consumption against engine running time rather than just a fuel-gauge estimate, a sudden mismatch between logged consumption and tank level is exactly the signature of siphoning or an unauthorised draw, and it shows up in the data rather than depending on a driver noticing.
| Model | Selection Guide (Engine Power) |
|---|---|
| BT-DOFS-006 | Up to 200 kW |
| BT-DOFS-008 | 200 to 400 kW |
| BT-DOFS-012 | 400 to 1000 kW |
| BT-DOFS-020 | 1000 to 1500 kW |
| BT-DOFS-025 | 1500 to 2000 kW |
Choose the options you need. Every selection is included automatically when you send the request — so the price you get back is for the unit you actually want.