Vortex flow meters operate on the von Karman effect, built around a bluff body. As fluid flows past it, alternating vortices form behind the bluff body — detected by a sensor, with the frequency of their formation directly proportional to fluid velocity, letting the meter accurately calculate flow rate.
Measurement of hydrocarbons and natural gas flow in pipelines; monitoring flow rates in refineries and petrochemical plants. Gas: air, oxygen, nitrogen, coal gas, natural gas, chemical gas and more. Liquid: high-temperature water, chemical liquid, clean and low-viscosity liquid. Steam: saturated and superheated steam.
Click any industry to see the full product list for it, or tell us your process and we will confirm the match.
Yes — one meter family covers all three: liquid at 0.5–7 m/s, gas at 5–70 m/s, and steam at 5–80 m/s, rated to 30 Bar and 350°C.
±0.5% for liquid, 1% for gas, with 0.2% repeatability.
SS316 or PA66 enclosure, with SS316, PTFE or PA66 lining, for sandwich or flange connection.
Hydrocarbon and natural gas pipelines, refineries and petrochemical plants, and general gas measurement — air, oxygen, nitrogen, coal gas, natural gas and other chemical gases.
No — it's a robust, easy-to-install design with low maintenance requirements since there's no rotor or moving part in the flow path.
Yes — every vortex meter has a low-flow cutoff, a velocity below which vortices simply don't shed regularly enough to detect, so the output clamps to zero rather than reporting an unreliable number. It's a real physical limit, not a setting we can remove, and it shifts with your fluid's viscosity and density. When you tell us your minimum expected flow alongside the maximum, we size the meter so that minimum sits comfortably above the cutoff rather than in the dead zone.
It can — strong pipe or process vibration can register as a signal alongside the real vortex shedding, since both show up as pressure fluctuations at the sensor. Noise-rejection filtering handles moderate cases, though pushing it harder to reject heavy vibration also raises the meter's low-flow cutoff, so it's better solved by proper pipe support and mounting than by filtering alone. Mention any nearby pumps or known vibration sources when you send us your line details.
| Model | Water Flow Range (m³/hr) | Air Flow Range (m³/hr) |
|---|---|---|
| BT-VTM-015 | 0.36 ~ 5.07 | 3.62 ~ 47.05 |
| BT-VTM-020 | 0.57 ~ 7.92 | 5.65 ~ 73.51 |
| BT-VTM-025 | 0.81 ~ 11.40 | 8.14 ~ 105.86 |
| BT-VTM-040 | 2.04 ~ 28.58 | 20.41 ~ 326.63 |
| BT-VTM-050 | 3.53 ~ 49.48 | 35.34 ~ 565.49 |
| BT-VTM-080 | 7.74 ~ 108.38 | 77.42 ~ 1238.64 |
| BT-VTM-100 | 13.30 ~ 186.22 | 133.02 ~ 2128.27 |
| BT-VTM-150 | 30.13 ~ 421.89 | 301.35 ~ 4821.57 |
| BT-VTM-200 | 56.55 ~ 791.68 | 565.49 ~ 9047.79 |
| BT-VTM-250 | 90.49 ~ 1266.87 | 904.91 ~ 14478.49 |
| BT-VTM-300 | 127.23 ~ 1781.28 | 1272.35 ~ 20357.52 |
Choose the options you need. Every selection is included automatically when you send the request — so the price you get back is for the unit you actually want.